Structure |
All-in-one structure, the door uses explosion-proof lock and explosion-proof chain |
Max. short-circuit current |
1000A |
Internal Resistance |
80±20 mΩ (Load-current 400A) |
Remote Control Available Distance |
7 meters without solid barrier |
Controlling Mode |
PLC touch type (7 inch) + remote control |
Mechanical Life |
300 thousand times |
Electric Life |
Resistive load 50,000 times |
Temperature Range |
Normal temperature to 80°C or 0-80°C (Optional) |
Temperature Fluctuation |
±1℃ |
Temperature Deviation |
±2℃ |
Inner Chamber Dimension |
W600 X D500 X H600mm |
Inner Chamber Material |
1.0mm thickness 304# stainless steel |
External Chamber Dimension |
W940XD780XH1620 mm |
External Chamber Material |
Cold-rolled sheet paint with1.5mm thickness, total thickness together with inner chamber is 100mm) |
Observation Window |
390 X 360mm (20mm thick explosion-proof tempered glass) and protective steel mesh |
Power Supply |
AC220V / 3.0KW |
Data Output |
Current and voltage temperature can be recorded with the interface display. The test data can be directly output by USB flash disk |
Security System |
Explosion-proof pressure relief device, smoke exhaust device, fire extinguishing system, electronic door lock system, safety stop switch |
Options |