Maximum working current (A)
|
1000
|
2000
|
3000
|
5000
|
10000
|
Rated insulation voltage (V)
|
1000
|
System resistance
|
≤100mΩ
|
≤5mΩ
|
Accessibility
|
Voltage, current, temperature collection, video monitoring system, fire extinguishing system, safety explosion-proof system, smoke exhaust system, smoke filter system
|
Test environment
|
Room temperature
|
Operation method
|
Long-distance wireless control
|
Explosion-proof box specifications (mm)
|
500x500x500、800x800x800、1000x1000x1000 Can be customized according to requirements
|
Dimensions
|
Subject to actual design
|
Configuration indicators
|
Voltage selection
|
0-10V,0-100V,0-1000V
|
Temperature collection range
|
-200℃~1200℃
|
Voltage and temperature accuracy
|
±1%FS
|
Voltage resolution
|
1mV
|
Temperature resolution
|
0.1℃
|
Main Specifications
|
Maximum instantaneous current
|
1500A
|
2500A
|
3500A
|
6000A
|
12000A
|
Response time
|
≤5μs
|
Short-circuit residence time
|
0~999S, time and status can be adjusted at will
|
Current accuracy
|
±1%FSR, resolution: 0.1A
|
Maximum size of specimen
|
1000x1000x1000mm
|
Resistance material
|
all bronze
|
Action time
|
Pull-in time/release time less than 30ms
|
Drive way
|
Electric, pneumatic
|
Temperature control explosion-proof box index
|
Temperature range
|
0℃~100℃(Adjustable)
|
control precision
|
0.01℃
|
Temperature fluctuation
|
±0.5℃
|
Temperature uniformity
|
±2℃
|
compressor
|
France Taikang Compressor
|
Observation window
|
Rectangular multi-layer high-resistance laminated tempered explosion-proof glass with stainless steel protective net
|
Explosion-proof pressure relief device
|
Box with automatic pressure relief device
|
Exhaust system
|
Exhaust system on the top of the box
|
Structure
|
Box
|
The vertical or horizontal structure is separated from the control part
|
communication
|
Using R232, 485 communication interface, can ensure the stability and real-time performance of remote collection, with explosion-proof function
|
Fixed furniture
|
Terminal or customer-supplied sample custom fixture
|
Data acquisition module
|
Independent remote collection and isolation, multiple voltage, temperature, and current collection channels to ensure correct data.
|
Number of channels standard
|
2 channels, 4 channels, 8 channels, multiple data acquisition systems, optional
|
Camera monitoring system
|
The test area is equipped with a high-definition camera monitoring system, which can be remotely controlled, and has an explosion-proof function
|
The standard configuration
|
Short-circuit host, data acquisition system, explosion-proof system (video monitoring, fire extinguishing system, smoke exhaust system optional)
|
Safety protection
|
Leakage, over temperature, over voltage, overload, over current protection, abnormal sound and light alarm, smoke alarm light
|
Test Fixture
|
Specific production, according to the actual use conditions of the sample
|
Voltage
|
AC220V 50HZ
|
Use environment
|
0℃~45℃
|