• 225L-2-slot Cold and Hot Impact Test Room
  • 225L-2-slot Cold and Hot Impact Test Room
  • 225L-2-slot Cold and Hot Impact Test Room
  • 225L-2-slot Cold and Hot Impact Test Room
  • 225L-2-slot Cold and Hot Impact Test Room
  • 225L-2-slot Cold and Hot Impact Test Room
  • 225L-2-slot Cold and Hot Impact Test Room
  • 225L-2-slot Cold and Hot Impact Test Room
  • 225L-2-slot Cold and Hot Impact Test Room
  • 225L-2-slot Cold and Hot Impact Test Room
  • 225L-2-slot Cold and Hot Impact Test Room
  • 225L-2-slot Cold and Hot Impact Test Room
  • 225L-2-slot Cold and Hot Impact Test Room
  • 225L-2-slot Cold and Hot Impact Test Room

225L-2-slot Cold and Hot Impact Test Room

Model No.︰

HMZ2012A225L

Brand Name︰

HarmonyWOLRD/OEM/ODM

Country of Origin︰

China

Unit Price︰

-

Minimum Order︰

1 pc

Share on:

Product Description

The cold and hot impact testing machine is also known as the high and low temperature impact testing chamber, and Taiwan is called the cold and hot impact testing machine, which is used to test the endurance of the material structure or composite material under the continuous environment of extremely high temperature and extremely low temperature in an instant, so as to test the chemical change or physical damage caused by thermal expansion and contraction in the shortest time. The test chamber is divided into two parts: high temperature zone and low temperature zone. The test sample is placed in the mobile basket. The unique heat storage and cold storage structure is adopted. The cylinder drives the basket to move up and down in the cold and hot bath to complete the cold and hot temperature impact test; Applicable objects include metal, plastic, rubber, electronics Such materials can be used as the basis or reference for product improvement.

1. GB/T2423.1-1989 Low temperature test method;

2. GB/T2423.2-1989 High temperature test method;

3. GB/T2423.22-1989 Temperature change test;

4. GJB150.5-86 Temperature impact test;

5. GJB360.7-87 Temperature impact test;

6. GJB367.2-87 405 Temperature impact test.

It is used for the physical changes of electronic and electrical components, automation components, communication components, auto parts, metals, chemical materials, plastics and other industries, national defense industry, aerospace, military industry, BGA, PCB base plates, electronic chip IC, semiconductor ceramic magnets and polymer materials, testing the repeated tensile force of its materials to high and low temperatures, and the chemical changes or physical damage of the products produced by thermal expansion and contraction, to confirm the quality of the products, From precision IC to components of heavy machinery, it is an ideal test tool

 

Applicable to aviation, military industry, ships, electricians, electronics, instruments and meters; medical apparatus and instruments; Civil nuclear energy; Colleges and universities; Research Institute; Commodity inspection, arbitration and technical supervision departments; Building materials ceramics; High and low temperature impact test of petrochemical products, complete machines and components.

Temperature range of high and low temperature storage area

 

A. High temperature zone:+60 ℃~+200 ℃

 

B. Low temperature zone: - 10 ℃~- 40 ℃;

 

Test temperature range in high and low temperature zone

 

A. High temperature zone:+60 ℃~+150 ℃

 

B. Low temperature zone: - 10 ℃~- 40 ℃;

 

control accuracy

 

±2℃;

 

Analytical accuracy

 

0.01℃;

 

Temperature rise time in high temperature zone

 

It takes about 35 minutes for RT (room temperature) to+200 ℃ (room temperature is+5~+30 ℃)

 

Cooling time in low temperature zone

 

RT (room temperature)~- 40 ℃ takes about 50min (room temperature is+5~+30 ℃)

 

Switching time and temperature recovery time

 

A. The switching time between the high and low temperature zones during the impact of the chlorophytum comosum of the test sample takes about 10sec

 

B. The temperature recovery time after switching between high and low temperature zones during the impact of test sample chlorophytum comosum is:

 

3min~5min (stabilization time of each impact temperature point ≥ 30min)

 

Equipment noise

 

Below 75dB

 

Weight of test object

 

10Kg

 

Size of high and low temperature test area

 

50cm(W)*50cm(H)*50cm(D);

 

External dimension: (approx.):

 

140cm(W)*180cm(H)*142cm(D)

 

Size of test sample chlorophytum comosum

 

30cm(W)*40cm(H)*30cm(D)

 

Inner box material

 

SUS # 304 heat and cold resistant stainless steel. Primary light panel

 

Outer box material

 

SUS # 304 heat and cold resistant stainless steel

 

Thermal insulation material

 

High-density glass wool and high-strength PU foam insulation material

 

Antiperspiration mechanism

 

Thermal insulation layer and door frame defrosting line are slightly hot and sweat-proof

 

accessory equipment

 

Cold and heat resistant high tension pressing, can withstand high temperature 300 ℃, low temperature - 100



Product Image

Copyright 2011-2023 Himcnc.com. All rights reserved.

Powered by DIYTrade.com